LSLV0008S100
Single phase (220 – 240V) variable frequency drive from LSIS, type LSLV0008S100. Power is 750 Watt.
Beschrijving
Single phase (220 – 240V) variable frequency drive from LSIS, type LSLV0008S100. Power is 750 Watt.
S100-Overview
Powerful sensorless control, and a diverse range of user friendly functions delivers added value to our customers.

Download Flyer S100 IP66 protection
Main Features:
- Selectable V/f, sensorless vector control,
- Single phase 220-240V (also 3 phase models available),
- Power range 0 – 75 KW,
- Build in EMC filter,
- Safety Torque Off (STO) build in,
- Certification: CE, UL, etc.,
- Side by side installation,
- PLC functions embedded (with sequence operation),
- Compliance with Open field Networks (Profibus-DP, Canopen, Ethernet),
- Smart copier function,
- IP20 & IP66 enclosures available;
Frame Design
IP20 | |
![]() |
|
IP66/NEMA4X | |
![]() |
|
Strong Performance
|
|
![]() |
Powerful sensorless control Starting torque of 200%/0.5Hz is produced and provides robust power in the low speed region.Powerful sensorless control Standstill auto-tuning is equipped to find motor constant without rotation under conditions where the system is installed or motor cannot rotate.> 100~240V in one coil(up to 220kW,400A)Powerful sensorless control Inverter capable fo quick reliable smooth restarts into bi-directional rotating loads. |
Space efficient Design
Side by Side installation
Minimized distance between products enables control panel size reduction when installing multiple AC Drive.
|
|
![]() |
|
Smaller Size Main parts are optimally arranged inside through the use of thermal radiation analysis and 3-dimensional design to reduce the dimensions by up to 60%(volume based) compared to the previous product(iG5A) |
|
![]() |
![]() |
Standard Compliance
![]() |
Built-in DC reactor – Effective in improving power factor and decreasing THD. ※ 3-phase 400V 30~75kWBuilt-in EMC filter – Meets the electrical noise reduction regulation. Related standards : 2nd Environment / Category C3 (Class A) CE standard is certified ※ C2 : 1-phase 200V 0.4~2.2kW ※ C3 : 3-phase 400V 0.4~75kWGlobal compliance (UL, CE) – Global standard compliance ※ UL, CE, Gost, C-tick and cULDual rating operation – It is designed to choose between heavy and normal duty operation.Overload capacity ※ Heavy duty operation : 150% of rated current, 60 seconds ※ Normal duty operation : 120% of rated current, 60 secondsVarious field networks – Able to deal with a variety of field networks Easy maintenance and mounting.Various field bus options – Profibus, Ethernet IP, Modbus TCP, CANopen Easy to install and use |
Safety Function
Built-in Safety Torque Off(STO)
The Safety input function meets EN ISO 13849-1 PLd and EN 61508 SIL2 (En 60204-1, stop category 0). This feature is equipped and enables you to meet current safety standards.
|
|
![]() |
Suitable for Users
Simple cooling fan replacement
|
Smart copier
|
|
![]() |
![]() |
|
Replaceable fan without complete disassembly. | 1. Smart copier allows users to download & upload the parameters from/to S100 without AC input power. 2. Customized main firmware is able to be downloaded to S100 using Smart copier. 3. Firmware of main control and I/O saved in Smart copier can be downloaded to S100 |
|
Multi-keypad function | Conduit option | |
![]() |
![]() |
|
– Single LCD keypad can be used to set up the parameters of a RS485 connected drives. – LCD keypad (same as iS7 model) is used to easily set up the parameters. Parameters can be copied to other drives. – Multi language support will be available. |
– S100 meets UL type 1 with this option. | |
Flange option | ||
![]() |
||
S100 allows its heatsink to be installed outside of panel for better cooling system with this option. |
Specification
1-Phase 200V (0.4~2.2kW)
LSLV S100-1 | 0004 | 0008 | 0015 | 0022 | ||
---|---|---|---|---|---|---|
Motor Rating |
Heavy Duty(HD) |
HP | 0.5 | 1.0 | 2.0 | 3.0 |
kW | 0.4 | 0.75 | 1.5 | 2.2 | ||
Normal Duty(ND) |
HP | 1.0 | 2.0 | 3.0 | 5.0 | |
kW | 0.75 | 1.5 | 2.2 | 3.7 | ||
Output Rating |
Capacity [kVA] |
Heavy Duty(HD) | 1.0 | 1.9 | 3.0 | 4.2 |
Normal Duty(ND) | 1.2 | 2.3 | 3.8 | 4.6 | ||
Rated Current |
Heavy Duty(HD) | 2.5 | 5.0 | 8.0 | 11.0 | |
Normal Duty(ND) | 3.1 | 6.0 | 10.0 | 12.0 | ||
Frequency [Hz] | 0~400Hz (IM Sensorless : 0~120[Hz]) | |||||
Voltage[V] | 3-phase 200~240V | |||||
Input Rating |
Voltage[V] | 1-phase 200~240VAC (-15% ~ +10%) | ||||
Frequency [Hz] | 50~60Hz(±5%) | |||||
Rated Current[A] |
Heavy Duty(HD) | 4.4 | 9.3 | 15.6 | 21.7 | |
Normal Duty(HD) | 5.8 | 11.7 | 19.7 | 24.0 | ||
Weight [kg] | 0.9 | 1.3 | 1.5 | 2.0 |
Dimensions
2.LSLV0004S100-1 / 0008S100-2 / 0008S100-4
.jpg)
Drive capacity | W1 | W2 | H1 | H2 | H3 | D1 | A | B | Ø | weight |
---|---|---|---|---|---|---|---|---|---|---|
LSLV0004S100-1 | 68 (2.68) | 59 (2.32) | 128 (5.04) | 120 (4.72) | 4.5 (0.18) | 128 (5.04) | 4.5 (0.16) | 4 (0.16) | 4 (0.16) | 0.88 |
LSLV0008S100-2 | 68 (2.68) | 59 (2.32) | 128 (5.04) | 120 (4.72) | 4.5 (0.18) | 128 (5.04) | 4.5 (0.16) | 4 (0.16) | 4 (0.16) | 0.88 |
LSLV0008S100-4 | 68 (2.68) | 59 (2.32) | 128 (5.04) | 120 (4.72) | 4.5 (0.18) | 128 (5.04) | 4.5 (0.16) | 4 (0.16) | 4 (0.16) | 0.88 |
3.LSLV0008S100-1 / 0015S100-2 / 0015S100-4
.jpg)
Drive capacity | W1 | W2 | H1 | H2 | H3 | D1 | A | B | Ø | weight |
---|---|---|---|---|---|---|---|---|---|---|
LSLV0008S100-1 | 100 (3.94) | 91 (3.58) | 128 (5.04) | 120 (4.72) | 4.5 (0.18) | 130 (5.12) | 4.5 (0.18) | 4.5 (0.18) | 4.5 (0.18) | 1.3 |
LSLV0015S100-2 | 100 (3.94) | 91 (3.58) | 128 (5.04) | 120 (4.72) | 4.5 (0.18) | 130 (5.12) | 4.5 (0.18) | 4.5 (0.18) | 4.5 (0.18) | 1.3 |
LSLV0015S100-4 | 100 (3.94) | 91 (3.58) | 128 (5.04) | 120 (4.72) | 4.5 (0.18) | 130 (5.12) | 4.5 (0.18) | 4.5 (0.18) | 4.5 (0.18) | 1.3 |
23.Flange option

Drive capacity | W | H | D1 | D2 | A1 | A2 | B1 | B2 | B3 | Ø | weight |
---|---|---|---|---|---|---|---|---|---|---|---|
LSLV0055S100-2 | 206 (8.11) | 276.5 (10.89) |
140 (5.51) | 55.1 (2.17) | 190 (7.48) | 176 (6.93) | 233 (9.17) | 151.5 (5.96) | 43.6 (1.72) | 6 (0.24) | 3.7 |
LSLV0055S100-4 | 206 (8.11) | 276.5 (10.89) |
140 (5.51) | 55.1 (2.17) | 190 (7.48) | 176 (6.93) | 233 (9.17) | 151.5 (5.96) | 43.6 (1.72) | 6 (0.24) | 3.7 |
LSLV0075S100-2 | 206 (8.11) |
276.5 (10.89) |
140 (5.51) |
55.1 (2.17) |
190 (7.48) |
176 (6.93) |
233 (9.17) |
151.5 (5.96) |
43.6 (1.72) |
6 (0.24) |
3.7 |
LSLV0075S100-4 | 206 (8.11) |
276.5 (10.89) |
140 (5.51) |
55.1 (2.17) |
190 (7.48) |
176 (6.93) |
233 (9.17) |
151.5 (5.96) |
43.6 (1.72) |
6 (0.24) |
3.7 |
LSLV0110S100-2 | 225.2 (8.87) |
338.7 (13.34) |
163 (6.42) |
72.1 (2.84) |
209.2 (8.24) |
195.5 (7.70) |
290.5 (11.44) |
208.7 (8.22) |
43.7 (1.72) |
6 (0.24) |
5.15 |
LSLV0110S100-4 | 225.2 (8.87) |
338.7 (13.34) |
163 (6.42) |
72.1 (2.84) |
209.2 (8.24) |
195.5 (7.70) |
290.5 (11.44) |
208.7 (8.22) |
43.7 (1.72) |
6 (0.24) |
5.15 |
LSLV0150S100-2 | 267 (10.51) |
403.5 (15.89) |
187 (7.36) |
93.6 (3.69) |
251 (9.88) |
251 (9.88) |
350 (13.78) |
247.5 (9.74) |
52.5 (2.07) |
6 (0.24) |
5.4 |
LSLV0150S100-4 | 225.2 (8.87) |
338.7 (13.34) |
163 (6.42) |
72.1 (2.84) |
209.2 (8.24) |
195.5 (7.70) |
290.5 (11.44) |
208.7 (8.22) |
43.7 (1.72) |
6 (0.24) |
5.15 |
LSLV0185S100-4 | 267 (10.51) |
403.5 (15.89) |
187 (7.36) |
93.6 (3.69) |
251 (9.88) |
251 (9.88) |
350 (13.78) |
247.5 (9.74) |
52.5 (2.07) |
6 (0.24) |
8.3 |
LSLV0220S100-4 | 267 (10.51) |
403.5 (15.89) |
187 (7.36) |
93.6 (3.69) |
251 (9.88) |
251 (9.88) |
350 (13.78) |
247.5 (9.74) |
52.5 (2.07) |
6 (0.24) |
8.3 |
24.Flange option